  • SMC AFM40P - 060AS:A FRL With Mist Separators And Air Actuators

SMC AFM40P - 060AS:A FRL With Mist Separators And Air Actuators

The SMC AFM40P-060AS is a smc frl core specifically designed for the AFM40 series smc mist separator, boasting a filtration accuracy of 0.3μm. It efficiently removes oil mist and solid impurities from compressed air. This smc frl core plays a crucial role in the field ···

  • Contact Us Contact On WhatsApp
  • 010-64225983

    +8613811814778

    info@zhongpingtech.com

    Building 26, Liyuan Community, Chaoyang District, Beijing, China

The SMC AFM40P-060AS is a smc frl core specifically designed for the AFM40 series smc mist separator, boasting a filtration accuracy of 0.3μm. It efficiently removes oil mist and solid impurities from compressed air. This smc frl core plays a crucial role in the field of industrial automation and is widely used in various scenarios that require high-precision air actuator processing.

SMC AFM40P - 060AS:A FRL With Mist Separators And Air Actuators

Product Specifications

Filtration Accuracy: 0.3μm

Applicable Models: AFM40-A, AFM40-06-A series smc mist separator

Pipe Connection Size: Below 1/2 inch

Rated Pressure: 0-1MPa

Product Features

High-Efficiency Filtration: Effectively removes oil mist and solid impurities larger than 0.3μm from compressed air, ensuring the cleanliness of the air source.

Transparent Cup Protective Cover: Enhances visual confirmation and safety, making it easy to monitor the smc frl core's usage.

Float-Type Automatic Drainage Device: Optional N.C. (Normally Closed) or N.O. (Normally Open) types, with minimum operating pressures of 0.15MPa and 0.1MPa, respectively.

Application Scenarios The AFM40P-060AS smc frl core is widely used in the following scenarios:

Industrial Automation Production Lines: Provides clean air sourcesfor pneumatic equipment, extending the service life of the equipment and improving production efficiency.

Machine Processing Workshops: Removes oil mist generated during the processing, improving the working environment and ensuring the health of workers.

Electronic Manufacturing Industry: Ensures the high purity of the air actuator during the production of electronic components, preventing contamination of sensitive components.

Usage Instructions Installation and Wiring

Installation Environment: Choose a well-ventilated, dust-free, and non-corrosive gas environment for installation, avoiding high temperatures, high humidity, or strong electromagnetic interference.

Wiring Requirements: Strictly follow the wiring diagram in the product manual to ensure the correct connection of power lines, signal lines, and motor lines.

Parameter Settings

Basic Parameter Settings: Set the replacement cycle and maintenance reminders for the smc frl core according to actual application needs.

Advanced Function Configuration: Such as the setting of automatic drainage functions, configure reasonably according to the usage environment and working frequency.

Maintenance and Inspection

Regular Inspection: Check the appearance of the smc frl core for damage, dust accumulation in the cup, and the normal operation of the drainage system.

Parameter Verification: Regularly verify the filtration effect of the smc frl core to ensure it meets the actual application requirements.

Fault Diagnosis: When the equipment fails, promptly check the fault code and troubleshoot according to the fault diagnosis guide in the manual.

Precautions

Environmental Conditions: Avoid using in environments containing synthetic oils, organic solvents, chemical drugs, cutting oils, etc., to prevent affecting the performance and service life of the smc frl core.

Maintenance Cycle: It is recommended to regularly replace the smc frl core. When the pressure drop between the IN and OUT ports is greater than 0.1MPa, the smc frl core should be replaced.

Safe Operation: Avoid contact with live parts during equipment operation to ensure the safety of operators. When performing maintenance and inspection, the power must be cut off, and the equipment must be completely stopped.

Frequently Asked Questions (FAQ)

1. How to Replace the AFM40P-060AS smc frl Core?

Replacement Steps: First, turn off the equipment power to ensure that the equipment is completely stopped. Then, open the maintenance door of the equipment, locate the smc frl core position according to the instructions in the manual, loosen the fixing bolts, remove the old smc frl core, install the new smc frl core, and ensure that it is securely installed.

Precautions: During the replacement process, avoid contaminating the smc frl core. If the smc frl core is damaged or blocked during use, it should be replaced immediately.

Maintenance Suggestions: It is recommended to regularly check the usage of the smc frl core and establish a reasonable replacement cycle according to the usage frequency and working environment of the equipment.

2. What is the Filtration Effect of the AFM40P-060AS smc frl Core?

Filtration Accuracy: The filtration accuracy of the AFM40P-060AS smc frl core is 0.3μm, which can effectively remove oil mist and solid impurities from compressed air.

Practical Application: In industrial automation production lines, this smc frl core can ensure the high purity of the air source, prevent contamination of pneumatic equipment, and extend the service life of the equipment.

Maintenance Suggestions: Regularly check the filtration effect of the smc frl core. If a decrease in filtration effect is found, the smc frl core should be replaced in time.

3. What are the Installation Requirements for the AFM40P-060AS smc frl Core?

Installation Environment: Choose a well-ventilated, dust-free, and non-corrosive gas environment for installation, avoiding high temperatures, high humidity, or strong electromagnetic interference.

Installation Method: Ensure that the smc frl core is installed vertically to facilitate drainage and air circulation. Use appropriate fixing methods during installation to avoid equipment damage caused by vibration.

Power Connection: When connecting the power supply, ensure that the specifications of the power line meet the requirements and pay attention to the correctness of the phase sequence. At the same time, ensure that the equipment is well grounded.

4. How Long is the Maintenance Cycle of the AFM40P-060AS smc frl Core?

Maintenance Cycle: It is recommended to regularly replace the smc frl core. When the pressure drop between the IN and OUT ports is greater than 0.1MPa, the smc frl core should be replaced.

Inspection Frequency: Regularly check the appearance of the smc frl core for damage, dust accumulation in the cup, and the normal operation of the drainage system.

Maintenance Suggestions: Establish a reasonable maintenance cycle according to the usage frequency and working environment of the equipment to ensure the efficient operation of the smc frl core.

5. What is the Applicable Range of the AFM40P-060AS smc frl Core?

Applicable Models: The AFM40P-060AS smc frl core is applicable to the AFM40-A and AFM40-06-A series smc mist separator.

Applicable Scenarios: It is widely used in industrial automation production lines, machine processing workshops, electronic manufacturing industries, and other scenarios that require high-precision air actuator processing.

Precautions: Before use, confirm the model of the equipment and the applicability of the smc frl core to ensure that the smc frl core matches the equipment.

6. What are the Installation Precautions for the AFM40P-060AS smc frl Core?

Installation Location: Choose a well-ventilated, dust-free, and non-corrosive gas environment for installation, avoiding high temperatures, high humidity, or strong electromagnetic interference.

Installation Method: Ensure that the smc frl core is installed vertically to facilitate drainage and air circulation. Use appropriate fixing methods during installation to avoid equipment damage caused by vibration.

Power Connection: When connecting the power supply, ensure that the specifications of the power line meet the requirements and pay attention to the correctness of the phase sequence. At the same time, ensure that the equipment is well grounded.

7. What are the Maintenance Suggestions for the AFM40P-060AS smc frl Core?

Regular Inspection: Check the appearance of the smc frl core for damage, dust accumulation in the cup, and the normal operation of the drainage system.

Parameter Verification: Regularly verify the filtration effect of the smc frl core to ensure it meets the actual application requirements.

Fault Diagnosis: When the equipment fails, promptly check the fault code and troubleshoot according to the fault diagnosis guide in the manual.

8. How Long is the Replacement Cycle of the AFM40P-060AS smc frl Core?

Replacement Cycle: It is recommended to regularly replace the smc frl core. When the pressure drop between the IN and OUT ports is greater than 0.1MPa, the smc frl core should be replaced.

Maintenance Suggestions: Establish a reasonable replacement cycle according to the usage frequency and working environment of the equipment to ensure the efficient operation of the smc frl core.

Precautions: During the replacement process, avoid contaminating the smc frl core. If the smc frl core is damaged or blocked during use, it should be replaced immediately.

9. What are the Applicable Environments for the AFM40P-060AS smc frl Core?

Applicable Environments: Choose a well-ventilated, dust-free, and non-corrosive gas environment for installation, avoiding high temperatures, high humidity, or strong electromagnetic interference.

Precautions: Avoid using in environments containing synthetic oils, organic solvents, chemical drugs, cutting oils, etc., to prevent affecting the performance and service life of the smc frl core.

Maintenance Suggestions: Regularly check the usage environment of the smc frl core to ensure it meets the requirements and prevent smc frl core damage caused by environmental issues.

10. What are the Installation Steps for the AFM40P-060AS Smc Frl Core?

Installation Steps: First, turn off the equipment power to ensure that the equipment is completely stopped. Then, open the maintenance door of the equipment, locate the smc frl core position according to the instructions in the manual, loosen the fixing bolts, remove the old smc frl core, install the new smc frl core, and ensure that it is securely installed.

Precautions: During the installation process, avoid contaminating the smc frl core. If the smc frl core is damaged or blocked during use, it should be replaced immediately.

Maintenance Suggestions: It is recommended to regularly check the usage of the smc frl core and establish a reasonable replacement cycle according to the usage frequency and working environment of the equipment.

Company Profile

Beijing ZhongPing Technology Co., Ltd.

Beijing Zhongping Technology Co., Ltd. is a leading one-stop provider for intelligent manufacturing, specializing in robotics, automation equipment, and core components. As a technology-driven enterprise, we integrate scientific research, design, marketing, technical services, and international trade.

With offices in key industrial regions and multiple global service points, we are committed to "making intelligent manufacturing simpler." Our focus on intelligence and digitalization positions us as a premier solution provider, driving advancements in the industry while enhancing productivity and efficiency for our clients.

Explore how we can elevate your manufacturing processes in today's dynamic industrial landscape.

  • 2000+

    Cooperative merchants

  • 1000

    Office space

  • 50000+

    Serve customers

  • 100+

    Industry experts

Proxy Certificate

  • HIKVISION robot
  • Siemens EP
  • Simphoenix/四方电气
  • Siemens ET
  • Hikvision/海康威视
  • ALIBABA

FAQ

1.Who are We?

Beijing Zhongping Technology Co., LTD., is a one-stop integrated service provider of intelligent manufacturing, belongs to the Gong Doctor Group, is a scientific research, design, marketing, technical services, industrial Internet, international import and export services as one of the science and technology companies.


2.What can you buy from us?

PLC, inverter, human-machine interface, hydraulic products, low-voltage power distribution, industrial robots and core components


3.Is the item in stock or need to be purchased from another supplier?

We have a large inventory of goods and have our own warehouse.


4.What advantages do we have over other suppliers?

Our company has a large amount of inventory and a number of warehouses, but also in the country's important industrial provinces and cities with offices and a number of overseas service points. To provide you with intelligent manufacturing one-stop comprehensive services, save efforts, labor and cost.


5.Can you provide 100% new original authentic products?

We only sell new original genuine, no renovation, no fake, only for the original factory original!


6.How long is the delivery time?

If there is a stock, it will take 2-3 working days to ship, if the quantity is large, it will take 5-7 working days after receiving the payment, if it is not a conventional model, it will take some time, we will inform you of the specific delivery time.


7.Is there technical support available?

Of course, we have a professional technical team that can help you solve technical problems.


8.How do we guarantee quality?

We have three processes to control the quality of goods.

1). Our engineers will inspect the production and quality control in the factory regularly.

2) Incoming materials shall be inspected by experienced purchasing engineers before they can be stored.

3). At least 2 people in the logistics department cross-check the goods to be sent before delivery.


9.Can you guarantee the safe and reliable delivery of your products?

Yes, we strictly adopt the international standard packing. We also use special packaging for dangerous goods, and refrigerated shipping for items with temperature requirements. Special item packaging and general cargo standard packaging requirements may incur additional costs.


10.How about the freight?

The cost depends on how you choose to get the goods. Express is usually the fastest but also the most expensive way. Sea freight is the best solution for large quantities of goods. The exact shipping cost depends on the purchase amount、quantity and weight of your order. Please feel free to contact us for more information.