The FX3-EBX300002 is a passive distributor box produced by SICK, belonging to the connection module series. It is primarily used to connect an encoder or a motor feedback system and can be connected with the motion control module FX3-MOC. This product boasts excellent compatibility and stability, making it suitable for a variety of industrial automation scenarios, effectively enhancing the reliability and maintenance efficiency of the system. The SICK module is designed with a PNP connection and PNP signal output, ensuring seamless integration and efficient signal transmission.

Product Details
Product Specifications
Model: FX3-EBX300002
Part Number: 2068728
Category: Connection Module
Connection Method: 15-pin D-Sub HD socket with PNP connection
Signal Distribution:
ENC1_A+: Encoder 1, signal pair A, positive signal with PNP signal output
ENC1_A–: Encoder 1, signal pair A, negative signal
ENC1_24V: 24V supply voltage for Encoder 1
ENC2_A+: Encoder 2, signal pair A, positive signal with PNP signal output
ENC2_A–: Encoder 2, signal pair A, negative signal
Product Features
Strong Compatibility: Compatible with a variety of encoders and motor feedback systems to ensure stable system operation. The SICK module ensures compatibility with PNP connection and PNP signal output.
Easy Installation: Standardized connection interfaces are provided for convenient connection with the motion control module FX3-MOC. The SICK module uses a PNP connection for easy setup.
Easy Maintenance: The simple design and clear signal distribution make it easy to troubleshoot and maintain. The SICK module with PNP signal output simplifies maintenance processes.
Application Scenarios
Industrial Automation: Used to connect encoders and motor feedback systems, widely applied in industries such as mechanical manufacturing, logistics conveyance, and food processing. The SICK module with PNP connection is ideal for these applications.
Motion Control: Works in conjunction with motion control modules to achieve precise motion control. The SICK module with PNP signal output ensures precise control.
Usage Instructions
Installation and Connection: Ensure correct connections, using appropriate cables and connectors to avoid signal interference. The SICK module with PNP connection should be connected properly.
Parameter Settings: Reasonably set encoder parameters according to actual application requirements. The SICK module with PNP signal output requires proper parameter settings for optimal performance.
Precautions
Environmental Conditions: Avoid using in high-temperature, high-humidity, or strong electromagnetic interference environments. The SICK module with PNP connection should be used in suitable environments.
Power Requirements: Ensure stable power supply voltage to prevent damage to equipment from voltage fluctuations. The SICK module with PNP signal output requires a stable power supply.
FAQ
What is the connection method of the FX3-EBX300002?
Connection Method: The FX3-EBX300002 provides a 15-pin D-Sub HD socket for connecting to the motion control module FX3-MOC using a PNP connection. Additionally, it offers a 9-pin D-Sub HD socket for connecting an extra motor feedback distributor box with PNP connection.
Connection Precautions: When connecting, ensure all interfaces and cables are correctly connected to avoid signal interference and power short circuits. The SICK module with PNP connection should be connected carefully.
Compatibility: This distributor box is compatible with a variety of encoders and motor feedback systems to ensure stable system operation. The SICK module with PNP connection ensures compatibility.
How to ensure the stable signal transmission of the FX3-EBX300002?
Signal Transmission Stability: Use shielded cables for connections and ensure the shielding layer of the cables is well-grounded to reduce electromagnetic interference. The SICK module with PNP signal output ensures stable signal transmission.
Signal Distribution: The distributor box provides clear signal distribution, including the positive and negative signals of the encoder and the supply voltage. The SICK module with PNP signal output simplifies signal distribution.
Maintenance and Care: Regularly check the condition of connection points and cables to ensure good contact and avoid signal transmission issues caused by poor contact. The SICK module with PNP connection should be maintained regularly.
What are the maintenance requirements for the FX3-EBX300002?
Visual Inspection: Regularly check the appearance of the distributor box for any damage or abnormalities, such as cracks in the casing or loose screws. The SICK module with PNP connection should be visually inspected.
Electrical Connection Check: Check the connections of power and signal lines to ensure they are secure and make good contact. The SICK module with PNP signal output should have its electrical connections checked.
Cleaning and Maintenance: Regularly clean the dust and debris around the distributor box to ensure good heat dissipation. The SICK module with PNP connection should be cleaned regularly.
What are the installation environment requirements for the FX3-EBX300002?
Environmental Conditions: Choose an environment with good ventilation, free from dust and corrosive gases for installation, and avoid installing the distributor box in high-temperature, high-humidity, or strong electromagnetic interference environments. The SICK module with PNP connection should be installed in a suitable environment.
Installation Method: Ensure the distributor box is installed vertically to facilitate heat dissipation. The SICK module with PNP connection should be installed vertically.
Power Connection: When connecting power, ensure the power cable meets the required specifications and pay attention to the correct phase sequence. The SICK module with PNP signal output should have its power connection checked.
How to set the signal distribution of the FX3-EBX300002?
Signal Distribution: The FX3-EBX300002 provides detailed signal distribution, including the positive and negative signals of the encoder and the supply voltage. The SICK module with PNP signal output provides clear signal distribution.
Setting Precautions: When setting the signal distribution, configure it reasonably according to actual application requirements to ensure the stability and accuracy of the signals. The SICK module with PNP connection should be configured properly.
Parameter Verification: Regularly verify the signal distribution settings to ensure they remain consistent with actual application requirements. The SICK module with PNP signal output should have its parameters verified regularly.
What are the power requirements for the FX3-EBX300002?
Power Requirements: Ensure the power supply voltage is stable to prevent damage to the equipment from voltage fluctuations. The SICK module with PNP connection requires a stable power supply.
Grounding Protection: Ensure the equipment is properly grounded in accordance with national and local electrical safety regulations. The SICK module with PNP signal output should be properly grounded.
Power Connection: When connecting power, ensure the power cable meets the required specifications and pay attention to the correct phase sequence. The SICK module with PNP connection should have its power connection checked.
How is the compatibility of the FX3-EBX300002?
Compatibility: The FX3-EBX300002 has good compatibility and can work with a variety of encoders and motor feedback systems. The SICK module with PNP connection ensures compatibility.
Application Range: Widely used in industries such as mechanical manufacturing, logistics conveyance, and food processing. The SICK module with PNP signal output is suitable for these industries.
Connection Module: The distributor box can be used in conjunction with the motion control module FX3-MOC to achieve precise motion control. The SICK module with PNP connection ensures seamless integration.
What are the installation precautions for the FX3-EBX300002?
Installation Location: Choose an environment with good ventilation, free from dust and corrosive gases for installation, and avoid installing the distributor box in high-temperature, high-humidity, or strong electromagnetic interference environments. The SICK module with PNP connection should be installed in a suitable location.
Installation Method: Ensure the distributor box is installed vertically to facilitate heat dissipation. The SICK module with PNP connection should be installed vertically.
Power Connection: When connecting power, ensure the power cable meets the required specifications and pay attention to the correct phase sequence. The SICK module with PNP signal output should have its power connection checked.
How to optimize the signal distribution of the FX3-EBX300002?
Signal Distribution Optimization: Use shielded cables for connections and ensure the shielding layer of the cables is well-grounded to reduce electromagnetic interference. The SICK module with PNP signal output ensures optimal signal distribution.
Signal Distribution Settings: Configure the signal distribution reasonably according to actual application requirements to ensure the stability and accuracy of the signals. The SICK module with PNP connection should be configured properly.
Parameter Verification: Regularly verify the signal distribution settings to ensure they remain consistent with actual application requirements. The SICK module with PNP signal output should have its parameters verified regularly.
What is the maintenance cycle for the FX3-EBX300002?
Maintenance Cycle: It is recommended to perform a comprehensive maintenance check every quarter. The SICK module with PNP connection should be maintained regularly.
Maintenance Content: This includes visual inspection, electrical connection check, cleaning and maintenance, etc. The SICK module with PNP signal output should be maintained thoroughly.
Maintenance Record: Keep maintenance records to track the operating status and maintenance history of the equipment. The SICK module with PNP connection should have its maintenance records kept.
What are the materials and manufacturing processes of the FX3-EBX300002?
Materials and Manufacturing Processes: The FX3-EBX300002 is made of high-quality materials and advanced manufacturing processes to ensure the durability and reliability of the product. Its casing is made of sturdy plastic or metal materials that can withstand various challenges in industrial environments. The SICK module with PNP connection is designed for durability.
Design Features: The product is designed to be compact for easy installation and maintenance. Its internal circuits are optimized to effectively reduce signal and electromagnetic interference. The SICK module with PNP signal output is designed for optimal performance.
Quality Control: SICK strictly controls quality during the production process to ensure that each product meets high-quality standards. The SICK module with PNP connection is subject to rigorous quality control.
What are the additional functions of the FX3-EBX300002?
Additional Functions: The FX3-EBX300002 offers a variety of additional functions, including signal distribution and power management. It can support connections to multiple encoders, meeting the signal distribution needs of complex systems. The SICK module with PNP connection provides these additional functions.
Expansion Capability: The product also supports expansion modules, allowing users to add additional connection modules according to actual needs to meet the connection requirements of more devices. The SICK module with PNP signal output supports expansion capabilities.
User-Friendliness: With clear signal distribution and easy-to-operate interface design, the FX3-EBX300002 provides a good user experience. The SICK module with PNP connection is user-friendly.
What are the product advantages of this item?
Product Advantages: The main advantages of the FX3-EBX300002 are its high compatibility and stability. It can work with a variety of encoders and motor feedback systems to ensure stable system operation. The SICK module with PNP connection and PNP signal output ensures these advantages.
Ease of Use: The product is designed to be simple, easy to install and maintain. Its standardized connection interfaces and clear signal distribution allow users to quickly complete installation and commissioning. The SICK module with PNP connection is easy to use.
Reliability: With high-quality materials and advanced manufacturing processes, the FX3-EBX300002 ensures long-term stable operation in harsh industrial environments. The SICK module with PNP signal output is reliable.
How is the after-sales service?
After-Sales Service: SICK provides comprehensive after-sales service, including technical support, product repair, and replacement. Users can contact SICK's customer service team at any time to obtain professional technical support. The SICK module with PNP connection is covered by this service.
Warranty Policy: The product offers limited warranty services. Specific terms can be referred to in S'sICK warranty policy. Within the warranty period, users can enjoy free repair and replacement services. The SICK module with PNP signal output is covered by this warranty.
Customer Feedback: SICK values customer feedback and continuously improves product and service quality to meet customer needs. The SICK module with PNP connection benefits from this feedback loop.
FAQ
1.Who are We?
Beijing Zhongping Technology Co., LTD., is a one-stop integrated service provider of intelligent manufacturing, belongs to the Gong Doctor Group, is a scientific research, design, marketing, technical services, industrial Internet, international import and export services as one of the science and technology companies.
2.What can you buy from us?
PLC, inverter, human-machine interface, hydraulic products, low-voltage power distribution, industrial robots and core components
3.Is the item in stock or need to be purchased from another supplier?
We have a large inventory of goods and have our own warehouse.
4.What advantages do we have over other suppliers?
Our company has a large amount of inventory and a number of warehouses, but also in the country's important industrial provinces and cities with offices and a number of overseas service points. To provide you with intelligent manufacturing one-stop comprehensive services, save efforts, labor and cost.
5.Can you provide 100% new original authentic products?
We only sell new original genuine, no renovation, no fake, only for the original factory original!
6.How long is the delivery time?
If there is a stock, it will take 2-3 working days to ship, if the quantity is large, it will take 5-7 working days after receiving the payment, if it is not a conventional model, it will take some time, we will inform you of the specific delivery time.
7.Is there technical support available?
Of course, we have a professional technical team that can help you solve technical problems.
8.How do we guarantee quality?
We have three processes to control the quality of goods.
1). Our engineers will inspect the production and quality control in the factory regularly.
2) Incoming materials shall be inspected by experienced purchasing engineers before they can be stored.
3). At least 2 people in the logistics department cross-check the goods to be sent before delivery.
9.Can you guarantee the safe and reliable delivery of your products?
Yes, we strictly adopt the international standard packing. We also use special packaging for dangerous goods, and refrigerated shipping for items with temperature requirements. Special item packaging and general cargo standard packaging requirements may incur additional costs.
10.How about the freight?
The cost depends on how you choose to get the goods. Express is usually the fastest but also the most expensive way. Sea freight is the best solution for large quantities of goods. The exact shipping cost depends on the purchase amount、quantity and weight of your order. Please feel free to contact us for more information.