SICK

  • IE200-F1: Magnetic Interlock For Switch Safety SICK Door Lock

IE200-F1: Magnetic Interlock For Switch Safety SICK Door Lock

The SICK iE200-F1 is an actuating element specifically designed for switch safety of electromechanical devices, compatible with sick door locks such as the i200 Lock and i110S with magnetic interlock. With its radial design and movable activation options, it ensures rel···

  • Contact Us Contact On WhatsApp
  • 010-64225983

    +8613811814778

    info@zhongpingtech.com

    Building 26, Liyuan Community, Chaoyang District, Beijing, China

The SICK iE200-F1 is an actuating element specifically designed for switch safety of electromechanical devices, compatible with sick door locks such as the i200 Lock and i110S with magnetic interlock. With its radial design and movable activation options, it ensures reliable locking and unlocking by magnetic interlock of sick door locks’ switch safety or protective devices. This product is suitable for applications where the minimum door radius is ≥80mm and is widely used in the field of industrial automation safety.

 

IE200-F1: Magnetic Interlock For Switch Safety SICK Door Lock

 

Product Specifications

Design: Radial construction.

Activation Options: Movable.

Minimum Door Radius: ≥80mm.

Dimensions: 52mm × 40mm × 31mm.

Installation Method: Suitable for radial mounting.

 

Product Features

High Compatibility: Works seamlessly with SICK's i200 Lock and i110S safety locking devices.

Flexible Design: The movable activation option allows for easy adaptation to various installation environments.

Safety Compliance: Meets international safety standards, ensuring reliability and safety in industrial settings.

 

Application Scenarios

The SICK iE200-F1 is primarily used in industrial automation safety scenarios, including:

Machine Tools and Automated Production Lines: Locking safety doors on machine tools and automated production lines.

Logistics and Warehousing: Securing protective doors in automated warehouses.

Robots and Automated Equipment: Ensuring safety during equipment operation to prevent accidental operations.

 

Installation and Usage Instructions

Installation and Wiring

Installation Environment: Choose a dust-free, non-corrosive, and low-electromagnetic-interference environment. Ensure good ventilation for the device.

Wiring Requirements: Follow the wiring diagram in the product manual carefully to ensure correct connections of power, signal, and control lines.

Grounding Protection: Ensure proper grounding of the device in accordance with national and local electrical safety regulations.

Parameter Settings and Commissioning

Function Testing: After installation, conduct mechanical and electrical function tests to ensure the device operates normally.

Regular Inspection: Periodically check for wear or damage to mechanical components and replace them as necessary.

 

Important Notes

Environmental Conditions: Avoid using the product in high-temperature, high-humidity, or high-electromagnetic-interference environments.

Power Requirements: Ensure stable power supply voltage to prevent damage to the device from voltage fluctuations.

Safety Operations: Avoid contact with live parts during device operation to ensure the safety of operators.

 

Frequently Asked Questions (FAQ)

How to Install the SICK iE200-F1?

Installation Steps: Select a suitable location that is dust-free, non-corrosive, and free from strong electromagnetic interference. Install the device vertically for proper ventilation.

Wiring Tips: Follow the manual for correct wiring of power, signal, and control lines, and ensure proper grounding.

Commissioning Suggestions: Conduct mechanical and electrical function tests after installation to ensure normal operation.

What Activation Methods Does the SICK iE200-F1 Offer?

Activation Options: The iE200-F1 features a movable activation method suitable for radial installation.

Compatibility: Compatible with SICK's i200 Lock and i110S safety locking devices.

Application Scenarios: Suitable for applications with a minimum door radius of ≥80mm.

What Are the Maintenance Requirements for the SICK iE200-F1?

Visual Inspection: Regularly check for damage or abnormalities, such as cracks in the housing or loose screws.

Electrical Connection Check: Ensure power and signal lines are securely connected and make good contact.

Mechanical Component Check: Inspect for wear or damage to mechanical parts and replace them if necessary.

How Safe Is the SICK iE200-F1?

Safety Standards: Complies with international safety standards like ISO 13849 and IEC 61508, ensuring reliability in critical applications.

Redundant Design: Features multiple redundancy and complex logic to quickly trigger safety mechanisms.

Troubleshooting: Refer to the manual for troubleshooting and handling based on fault codes.

What Is the Lifespan of the SICK iE200-F1?

Durability: Made with high-performance materials and designed for long-term stable operation in harsh environments.

Maintenance Tips: Regularly clean the device and cooling components to ensure proper airflow.

Replacement Advice: Replace the entire unit when wear or damage occurs to avoid replacing individual parts.

What Are the Signal Source Requirements for the SICK iE200-F1?

Signal Stability: Ensure a stable and interference-resistant signal source for normal operation.

Shielding Measures: Use shielded cables for signal connections and ensure proper grounding of the shielding layer.

Voltage Requirements: Ensure the signal source voltage matches the device requirements to avoid fluctuations.

How to Set the Frequency Setting Channel for the SICK iE200-F1?

Setting Methods: Frequency can be set via external signals or the device panel.

Signal Requirements: Ensure the stability and accuracy of external signals.

Parameter Configuration: Set the signal input range and corresponding frequency range based on actual needs.

What Control Modes Are Available for the SICK iE200-F1?

Control Mode Selection: Choose the appropriate control mode based on application needs, such as constant speed control.

Mode Features: Constant speed control is simple and easy to use, suitable for general constant speed applications.

Parameter Settings: Adjust parameters according to specific requirements after selecting the control mode.

What Cooling Methods Does the SICK iE200-F1 Use?

Cooling Methods: Uses natural cooling or forced air cooling, depending on the device model.

Installation Requirements: Ensure sufficient space around the device for proper airflow.

Maintenance: Regularly clean cooling components to ensure the cooling system operates normally.

What Are the Common Faults of the SICK iE200-F1?

Power Issues: Poor power connections or unstable voltage can cause device malfunction.

Signal Interference: External electromagnetic interference can affect signal lines and prevent normal operation.

Mechanical Failures: Damaged or poorly connected mechanical components can cause device malfunction.

 


Company Profile

Beijing ZhongPing Technology Co., Ltd.

Beijing Zhongping Technology Co., Ltd. is a leading one-stop provider for intelligent manufacturing, specializing in robotics, automation equipment, and core components. As a technology-driven enterprise, we integrate scientific research, design, marketing, technical services, and international trade.

With offices in key industrial regions and multiple global service points, we are committed to "making intelligent manufacturing simpler." Our focus on intelligence and digitalization positions us as a premier solution provider, driving advancements in the industry while enhancing productivity and efficiency for our clients.

Explore how we can elevate your manufacturing processes in today's dynamic industrial landscape.

  • 2000+

    Cooperative merchants

  • 1000

    Office space

  • 50000+

    Serve customers

  • 100+

    Industry experts

Proxy Certificate

  • HIKVISION robot
  • Siemens EP
  • Simphoenix/四方电气
  • Siemens ET
  • Hikvision/海康威视
  • ALIBABA

FAQ

1.Who are We?

Beijing Zhongping Technology Co., LTD., is a one-stop integrated service provider of intelligent manufacturing, belongs to the Gong Doctor Group, is a scientific research, design, marketing, technical services, industrial Internet, international import and export services as one of the science and technology companies.


2.What can you buy from us?

PLC, inverter, human-machine interface, hydraulic products, low-voltage power distribution, industrial robots and core components


3.Is the item in stock or need to be purchased from another supplier?

We have a large inventory of goods and have our own warehouse.


4.What advantages do we have over other suppliers?

Our company has a large amount of inventory and a number of warehouses, but also in the country's important industrial provinces and cities with offices and a number of overseas service points. To provide you with intelligent manufacturing one-stop comprehensive services, save efforts, labor and cost.


5.Can you provide 100% new original authentic products?

We only sell new original genuine, no renovation, no fake, only for the original factory original!


6.How long is the delivery time?

If there is a stock, it will take 2-3 working days to ship, if the quantity is large, it will take 5-7 working days after receiving the payment, if it is not a conventional model, it will take some time, we will inform you of the specific delivery time.


7.Is there technical support available?

Of course, we have a professional technical team that can help you solve technical problems.


8.How do we guarantee quality?

We have three processes to control the quality of goods.

1). Our engineers will inspect the production and quality control in the factory regularly.

2) Incoming materials shall be inspected by experienced purchasing engineers before they can be stored.

3). At least 2 people in the logistics department cross-check the goods to be sent before delivery.


9.Can you guarantee the safe and reliable delivery of your products?

Yes, we strictly adopt the international standard packing. We also use special packaging for dangerous goods, and refrigerated shipping for items with temperature requirements. Special item packaging and general cargo standard packaging requirements may incur additional costs.


10.How about the freight?

The cost depends on how you choose to get the goods. Express is usually the fastest but also the most expensive way. Sea freight is the best solution for large quantities of goods. The exact shipping cost depends on the purchase amount、quantity and weight of your order. Please feel free to contact us for more information.