SMC

  • SY5120-5LOU-C6F-Q Air Operated Solenoid With One-Touch Coupling

SY5120-5LOU-C6F-Q Air Operated Solenoid With One-Touch Coupling

The SMC SY5120-5LOU-C6F-Q is a air operated solenoid valve belonging to the SMC SY5000 series, featuring G one touch coupling accessories, 6 mm threads, die-cast aluminum material, and electromagnetic/smc pilot control.This air operated solenoid valve is suitable for a ···

  • Contact Us Contact On WhatsApp
  • 010-64225983

    +8613811814778

    info@zhongpingtech.com

    Building 26, Liyuan Community, Chaoyang District, Beijing, China

The SMC SY5120-5LOU-C6F-Q is a air operated solenoid valve belonging to the SMC SY5000 series, featuring G one touch coupling accessories, 6 mm threads, die-cast aluminum material, and electromagnetic/smc pilot control. 

SY5120-5LOU-C6F-Q Air Operated Solenoid With One-Touch Coupling

This air operated solenoid valve is suitable for a variety of industrial automation scenarios, such as robotic arms, conveying systems, and pressure control. Its compact design, energy efficiency, and suitability for vacuum environments ensure excellent sealing performance and long service life.

Product Specifications:

1.      Coil Voltage: 24V DC

2.      Operating Pressure Range: 0.15 → 0.7 MPa

3.      Maximum Operating Temperature: +50°C

4.      Interface Type: G one touch coupling accessories, 6 mm threads

5.      Installation Method: Manifold mounting

6.      Material: Die-cast aluminum

Product Features:

1.      Energy Efficient: Low power consumption design achieves energy-saving effects.

2.      Compact Size: Reduced valve body size helps save installation space, making it suitable for applications with limited space.

3.      High Reliability: Suitable for vacuum environments, ensuring excellent sealing performance and long service life.

4.      Easy Installation and Maintenance: Direct piping design simplifies the installation and maintenance process.

Application Scenarios:

1.      Robotic Arms: Used to control the precise movement of robotic arms.

2.      Conveying Systems: Controls the flow of materials in automated conveying systems.

3.      Pressure Control: Provides reliable fluid control in applications requiring precise pressure control.

Usage Instructions: Installation and Wiring:

1.      Installation Environment: Choose a well-ventilated, dust-free, and non-corrosive gas environment for installation. Avoid installing the air operated solenoid valve in high-temperature, high-humidity, or strong electromagnetic interference environments.

2.      Installation Method: Ensure the air operated solenoid valve is installed vertically for proper heat dissipation. Use appropriate fixing methods during installation to prevent vibration from affecting the equipment.

3.      Power Connection: When connecting the power supply, ensure the power cable meets the required specifications and pay attention to the correct phase sequence. Also, ensure the equipment is properly grounded.

Parameter Settings:

1.      Basic Parameter Settings: Includes motor parameters, control methods, frequency range, etc., set according to actual application needs. For example, for applications requiring high-precision control, choose the flux vector control mode.

2.      Advanced Function Configuration: Such as PID control, multi-speed control, etc., configure according to specific application scenarios to achieve more complex control functions.

Maintenance and Inspection:

1.      Regular Inspection: Check the appearance of the air operated solenoid valve for damage, dust on heat sinks, and proper operation of fans. Regularly clean the dust from heat sinks and fans to ensure the smooth operation of the cooling system.

2.      Parameter Verification: Regularly verify the parameter settings of the air operated solenoid valve to ensure they match the actual application needs.

3.      Fault Diagnosis: When the equipment fails, promptly check the fault code and follow the troubleshooting guide in the manual to identify and resolve the issue.

Precautions:

1.      Environmental Conditions: Avoid using the product in high-temperature, high-humidity, or strong electromagnetic interference environments to prevent affecting its performance and lifespan.

2.      Power Requirements: Ensure the power voltage is stable to avoid damage to the air operated solenoid valve from voltage fluctuations. After the equipment is powered off, wait for a certain period before powering it back on to prevent damage to the equipment.

3.      Safe Operation: Avoid contact with live parts during equipment operation to ensure the safety of operators. When performing maintenance and inspection, the power must be disconnected, and the capacitor must be fully discharged.

Frequently Asked Questions (FAQ):

1.      How to perform motor self-tuning?

   Importance of Motor Self-Tuning: Motor self-tuning is an essential step to ensure the matching of the inverter with the motor, improving control accuracy and system stability. When performing self-tuning, first set the motor's nameplate parameters, including motor power, rated voltage, and rated current.

   Precautions During Self-Tuning: During the self-tuning process, the inverter injects current into the motor. Therefore, it is crucial to ensure the motor is correctly connected to the inverter and that the inverter is in a ready state. Also, ensure the motor is stationary to avoid damage during self-tuning.

   Effects After Self-Tuning: After completing self-tuning, the inverter automatically adjusts control parameters based on the actual motor parameters to achieve optimal performance. This helps improve system response speed and control accuracy, meeting the demands of high-precision control applications.

2.      How to configure the communication interface of the SY5120-5LOU-C6F-Q?

   Communication Interface Type: The SY5120-5LOU-C6F-Q air operated solenoid valve itself does not support a communication interface but can be controlled through external controllers (such as PLCs). Users can choose the appropriate communication interface according to actual needs.

   Communication Line Connection: When configuring the communication interface, ensure the communication lines are correctly connected. Use shielded cables for connection and ensure the shielding layer is properly grounded to reduce electromagnetic interference.

  Communication Parameter Settings: According to the communication protocol requirements, set the controller's communication address, baud rate, data bits, stop bits, etc. Also, ensure the communication parameters match those of the upper-level machine to achieve a reliable communication connection.

3.      How to select the power range of the air operated solenoid valve?

   Choose Based on Load Demand: When selecting the power range of the air operated solenoid valve, determine it based on the actual load condition of the motor. If the load is light, choose a air operated solenoid valve that matches the motor's rated power; if the load is heavy or there is a significant starting torque requirement, choose a air operated solenoid valve with slightly higher power.

   Consider Safety Factor: When selecting the power range, also consider the safety factor of the system. It is usually recommended to choose a air operated solenoid valve with slightly higher power than the motor's rated power to cope with load fluctuations and emergencies.

   Overload Capability: The SY5120-5LOU-C6F-Q air operated solenoid valve has a certain overload capability and can withstand loads exceeding the rated power for a short time. However, long-term overload can affect the lifespan and performance of the air operated solenoid valve, so it is best to avoid long-term overload operation when selecting the power range.

4.      What is the cooling method of the SY5120-5LOU-C6F-Q?

   Cooling Method: The SY5120-5LOU-C6F-Q air operated solenoid valve uses natural cooling, dissipating heat through the valve body surface.

   Installation Requirements: When installing the air operated solenoid valve, ensure there is enough space around it for air circulation. Avoid installing the air operated solenoid valve in a closed or poorly ventilated environment to prevent affecting the cooling effect.

   Maintenance and Care: Regularly clean the dust from the valve body surface to effectively prevent equipment overheating due to poor cooling. Also, check if the valve body is securely installed to ensure its normal operation.

5.      How to avoid electromagnetic interference of the SY5120-5LOU-C6F-Q?

   Built-in Filter: The air operated solenoid valve itself does not produce electromagnetic interference, but external filters and shielding measures can be used to reduce electromagnetic interference.

  Wiring Precautions: When wiring, try to avoid placing signal lines close to power lines to reduce electromagnetic interference. Also, use shielded cables for signal line connections and ensure the shielding layer is properly grounded.

   Grounding Measures: Good grounding is an important means to reduce electromagnetic interference. Ensure the equipment is properly grounded and complies with national and local electrical safety regulations.

6.      What protection functions does the SY5120-5LOU-C6F-Q have?

   Overload Protection: When the motor load exceeds the rated value, the air operated solenoid valve will automatically reduce the frequency or stop running to protect the motor and air operated solenoid valve.

   Overheat Protection: The air operated solenoid valve is equipped with a temperature sensor inside. When the temperature exceeds the set value, it will automatically shut down to prevent damage from overheating.

  Overvoltage and Undervoltage Protection: When the power voltage is too high or too low, the air operated solenoid valve will automatically shut down to protect the equipment. Additionally, it has short-circuit protection and phase loss protection functions to ensure the safe operation of the system.

7.      How to perform regular maintenance on the air operated solenoid valve?

   Appearance Inspection: Regularly check the appearance of the air operated solenoid valve for damage or abnormalities, such as cracks in the housing or loose screws.

   Cooling System Maintenance: Clean the dust from the valve body surface to ensure the normal operation of the cooling system. Check if the valve body is securely installed and replace it if there are any abnormalities.

   Electrical Connection Inspection: Check if the power and signal lines are securely connected to ensure good contact. Also, check the operating state of the motor to promptly identify and resolve any abnormal conditions.

8.      What precautions should be taken when installing the air operated solenoid valve?

   Installation Location: Choose an environment with good ventilation, free of dust, and non-corrosive gases for installation. Avoid installing the air operated solenoid valve in high-temperature, high-humidity, or strong electromagnetic interference environments.

   Installation Method: Ensure the air operated solenoid valve is installed vertically for proper heat dissipation. Use appropriate fixing methods during installation to prevent vibration from affecting the equipment.

   Power Connection: When connecting the power supply, ensure the power cable meets the required specifications and pay attention to the correct phase sequence. Also, ensure the equipment is properly grounded.

9.      How to select the control mode of the SY5120-5LOU-C6F-Q?

   Choose Based on Application Needs: For applications requiring high-precision speed control, choose the sensorless vector control mode; for general constant-speed control applications, choose the V/F control mode.

  Control Mode Features: The sensorless vector control mode can achieve high-precision speed and torque control, suitable for applications with high control accuracy requirements. The V/F control mode is simple and easy to use, suitable for general constant-speed control.

  Parameter Settings: After selecting the control mode, set the parameters according to specific application needs to achieve the best control effect.

10.  How to set the frequency setting channel of the air operated solenoid valve?

   Frequency Setting Method: The frequency can be set through the air operated solenoid valve panel, external analog signals, or digital signals. Users can choose the appropriate frequency setting method according to actual application needs.

   Signal Source Requirements: When setting the frequency setting channel, ensure the stability and accuracy of the signal source. For example, when using external analog signals for frequency setting, ensure the stability and interference resistance of the signal.

   Parameter Configuration: According to the selected frequency setting method, perform the corresponding parameter configuration. For example, for external analog signal setting, set the input range of the signal and the corresponding frequency range.

Company Profile

Beijing ZhongPing Technology Co., Ltd.

Beijing Zhongping Technology Co., Ltd. is a leading one-stop provider for intelligent manufacturing, specializing in robotics, automation equipment, and core components. As a technology-driven enterprise, we integrate scientific research, design, marketing, technical services, and international trade.

With offices in key industrial regions and multiple global service points, we are committed to "making intelligent manufacturing simpler." Our focus on intelligence and digitalization positions us as a premier solution provider, driving advancements in the industry while enhancing productivity and efficiency for our clients.

Explore how we can elevate your manufacturing processes in today's dynamic industrial landscape.

  • 2000+

    Cooperative merchants

  • 1000

    Office space

  • 50000+

    Serve customers

  • 100+

    Industry experts

Proxy Certificate

  • HIKVISION robot
  • Siemens EP
  • Simphoenix/四方电气
  • Siemens ET
  • Hikvision/海康威视
  • ALIBABA

FAQ

1.Who are We?

Beijing Zhongping Technology Co., LTD., is a one-stop integrated service provider of intelligent manufacturing, belongs to the Gong Doctor Group, is a scientific research, design, marketing, technical services, industrial Internet, international import and export services as one of the science and technology companies.


2.What can you buy from us?

PLC, inverter, human-machine interface, hydraulic products, low-voltage power distribution, industrial robots and core components


3.Is the item in stock or need to be purchased from another supplier?

We have a large inventory of goods and have our own warehouse.


4.What advantages do we have over other suppliers?

Our company has a large amount of inventory and a number of warehouses, but also in the country's important industrial provinces and cities with offices and a number of overseas service points. To provide you with intelligent manufacturing one-stop comprehensive services, save efforts, labor and cost.


5.Can you provide 100% new original authentic products?

We only sell new original genuine, no renovation, no fake, only for the original factory original!


6.How long is the delivery time?

If there is a stock, it will take 2-3 working days to ship, if the quantity is large, it will take 5-7 working days after receiving the payment, if it is not a conventional model, it will take some time, we will inform you of the specific delivery time.


7.Is there technical support available?

Of course, we have a professional technical team that can help you solve technical problems.


8.How do we guarantee quality?

We have three processes to control the quality of goods.

1). Our engineers will inspect the production and quality control in the factory regularly.

2) Incoming materials shall be inspected by experienced purchasing engineers before they can be stored.

3). At least 2 people in the logistics department cross-check the goods to be sent before delivery.


9.Can you guarantee the safe and reliable delivery of your products?

Yes, we strictly adopt the international standard packing. We also use special packaging for dangerous goods, and refrigerated shipping for items with temperature requirements. Special item packaging and general cargo standard packaging requirements may incur additional costs.


10.How about the freight?

The cost depends on how you choose to get the goods. Express is usually the fastest but also the most expensive way. Sea freight is the best solution for large quantities of goods. The exact shipping cost depends on the purchase amount、quantity and weight of your order. Please feel free to contact us for more information.