The SMC VT307-5DZ1-01F-Q is a inline filter type smc solenoid valve, part of the VT307 series. This smc solenoid valve features a smc flow control (1.8W), with a single valve offering multiple functions, making it suitable for environments with low concentrations of ozone.
The main valve is made of HNBR rubber material, ensuring compatibility with the installation dimensions of the original product. Widely used in various pneumatic control systems, such as automated production lines, mechanical manufacturing, food processing, and more.
Product Specifications:
Rated Voltage: DC24V
Power Consumption: 1.8W
Rated Pressure: 0 → 0.7 MPa
Operating Temperature: -10°C to +50°C
Pipe Connection Size: 1/8 inch (6A)
Thread Type: Rc
Wiring Method: DIN-type plug with socket
Indicator Light and Overvoltage Protection Circuit: Equipped with indicator light and overvoltage protection circuit
Bracket: With bracket
CE Certification: None
Product Features:
Smc Flow Control: 1.8W, energy-saving and environmentally friendly.
Multi-functionality: A single valve offers multiple functions, such as N.C. (Normally Closed), N.O. (Normally Open),, selection, etc.
Low Concentration Ozone Countermeasures: The main valve is made of HNBR rubber material, suitable for environments with low concentrations of ozone and inline filter type.
Installation Interchangeability: Compatible with the installation dimensions of the original product, facilitating upgrades and replacements.
Modular Type: VV307, suitable for various pneumatic systems.
Application Scenarios:
Automated Production Lines: Used to control the on/off and actions of pneumatic cylinders, actuators, and other equipment.
Mechanical Manufacturing: In machines, robots, and other equipment, used to control pneumatic clamps, tools, and more.
Food Processing: In packaging, conveying, and other processes, used to control pneumatic valves and actuators.
Medical Equipment: In ventilators, anesthetizing machines, and other devices, used to control the on/off and flow of air circuits.
Usage Instructions:
Installation and Wiring:
Installation Environment: Choose a well-ventilated, dust-free, and non-corrosive gas environment for installation. Avoid installing the smc solenoid valve in high-temperature, high-humidity, or strong electromagnetic interference environments.
Installation Method: Ensure the smc solenoid valve is installed vertically for proper heat dissipation. Use appropriate fixing methods to avoid equipment damage from vibrations.
Power Connection: When connecting the power supply, ensure the power cable meets the required specifications and pay attention to the correct phase sequence. Also, ensure the equipment is properly grounded.
Signal Wire Connection: Use shielded cables for signal wire connections and ensure the shielding layer is properly grounded to reduce electromagnetic interference.
Parameter Settings:
Basic Parameter Settings: Include rated voltage, rated pressure, etc., set according to actual application requirements.
Advanced Function Configuration: Such as overvoltage protection, indicator light function, etc., configure according to specific application scenarios to achieve more complex control functions.
Maintenance and Inspection:
Regular Inspection: Check the appearance of the smc solenoid valve for damage, dust on heat sinks, and proper operation of fans. Regularly clean the dust from heat sinks and fans to ensure the smooth operation of the cooling system.
Parameter Verification: Regularly verify the parameter settings of the smc solenoid valve to ensure they match the actual application requirements.
Fault Diagnosis: When the equipment fails, promptly check the fault code and follow the troubleshooting guide in the manual to identify and resolve the issue.
Precautions:
Environmental Conditions: Avoid using the product in high-temperature, high-humidity, or strong electromagnetic interference environments to prevent affecting its performance and lifespan.
Power Requirements: Ensure the power voltage is stable to avoid damage to the smc solenoid valve from voltage fluctuations. After the equipment is powered off, wait for a certain period before powering it back on to avoid damage to the equipment.
Safe Operation: Avoid contact with live parts during equipment operation to ensure the safety of operators. When performing maintenance and inspection, the power must be disconnected, and the capacitor must be fully discharged.
Frequently Asked Questions (FAQ):
How to perform self-tuning of the smc solenoid valve?
Importance of Self-tuning: Self-tuning is an essential step to ensure the smc solenoid valve matches the pneumatic system, improving control accuracy and system stability. When performing self-tuning, first set the rated voltage, rated pressure, and other parameters of the smc solenoid valve.
Precautions During Self-tuning: During the self-tuning process, the smc solenoid valve will inspect the air circuit, so it is necessary to ensure the air circuit is correctly connected and the smc solenoid valve is in a ready state. Also, ensure there are no leaks in the air circuit to avoid damaging the smc solenoid valve during self-tuning.
Effects After Self-tuning: After completing self-tuning, the smc solenoid valve will automatically adjust the control parameters based on the actual parameters of the air circuit to achieve the best operating effect. This helps improve the system's response speed and control accuracy, meeting the application requirements for high-precision control.
How to configure the communication interface of the VT307-5DZ1-01F-Q smc solenoid valve?
Communication Interface Types: The VT307-5DZ1-01F-Q smc solenoid valve supports multiple voltage options, including DC24V, AC110V, AC220V, etc. Users can choose the appropriate voltage for configuration according to actual needs.
Communication Line Connection: When configuring the communication interface, ensure the communication line connection is correct. Use shielded cables for connection and ensure the shielding layer is properly grounded to reduce electromagnetic interference.
Communication Parameter Settings: According to the communication protocol requirements, set the communication address, baud rate, data bits, stop bits, and other parameters of the smc solenoid valve. Also, ensure the communication parameters are consistent with the upper computer to achieve a reliable communication connection.
How to choose the power range of the smc solenoid valve?
Selection Based on Load Demand: When choosing the power range of the smc solenoid valve, determine it based on the actual load of the pneumatic system. If the load is light, choose a smc solenoid valve with a power rating that matches the rated power; if the load is heavy or there is a significant starting torque requirement, choose a smc solenoid valve with a slightly higher power rating.
Consider Safety Factor: When selecting the power range, also consider the safety factor of the system. It is usually recommended to choose a smc solenoid valve with a power rating slightly higher than the rated power to cope with load fluctuations and emergencies.
Overload Capability: The VT307-5DZ1-01F-Q smc solenoid valve has a certain overload capability and can withstand a load exceeding the rated power for a short time. However, long-term overload can affect the lifespan and performance of the smc solenoid valve, so it is advisable to avoid long-term overload operation when selecting the power range.
What is the cooling method of the VT307-5DZ1-01F-Q smc solenoid valve?
Cooling Method: The VT307-5DZ1-01F-Q smc solenoid valve uses natural cooling, dissipating heat through the heat sink on the outer shell.
Installation Requirements: When installing the smc solenoid valve, ensure there is enough space around it for air circulation. Avoid installing the smc solenoid valve in a closed or poorly ventilated environment to prevent affecting the cooling effect.
Maintenance and Care: Regularly clean the dust from the heat sink to effectively prevent equipment overheating due to poor cooling. Also, check if the smc solenoid valve is securely installed to ensure its normal operation.
How to avoid electromagnetic interference of the VT307-5DZ1-01F-Q smc solenoid valve?
Built-in Filter: The smc solenoid valve is equipped with an EMC filter, complying with relevant electromagnetic compatibility standards, which can effectively suppress electromagnetic interference.
Wiring Precautions: When wiring, try to avoid placing signal wires close to power wires to reduce electromagnetic interference. Also, use shielded cables for signal wire connections and ensure the shielding layer is properly grounded.
Grounding Measures: Good grounding is an important means to reduce electromagnetic interference. Ensure the equipment is properly grounded and complies with national and local electrical safety regulations.
What are the protection functions of the VT307-5DZ1-01F-Q smc solenoid valve?
Overload Protection: When the load of the smc solenoid valve exceeds the rated value, it will automatically reduce the frequency or stop running to protect the smc solenoid valve and the pneumatic system.
Overheat Protection: The smc solenoid valve is equipped with a temperature sensor inside, which will automatically shut down when the temperature exceeds the set value to prevent damage caused by overheating.
Overvoltage and Undervoltage Protection: When the power voltage is too high or too low, the smc solenoid valve will automatically shut down to protect the equipment. In addition, it also has short-circuit protection and phase-loss protection functions to ensure the safe operation of the system.
How to perform regular maintenance on the smc solenoid valve?
Appearance Inspection: Regularly check the appearance of the smc solenoid valve for damage or abnormalities, such as cracks in the outer shell or loose screws.
Cooling System Maintenance: Clean the dust from the heat sink to ensure the normal operation of the cooling system. Check if the heat sink is securely installed and replace it in case of any abnormalities.
Electrical Connection Inspection: Check if the power and signal wire connections are secure to ensure good contact. Also, check if the air circuit connections are normal and promptly identify and resolve any abnormalities.
What precautions should be taken when installing the smc solenoid valve?
Installation Location: Choose an environment with good ventilation, free of dust, and non-corrosive gases for installation. Avoid installing the smc solenoid valve in high-temperature, high-humidity, or strong electromagnetic interference environments.
Installation Method: Ensure the smc solenoid valve is installed vertically for proper heat dissipation. Use appropriate fixing methods during installation to avoid equipment damage from vibrations.
Power Connection: When connecting the power supply, ensure the power cable meets the required specifications and pay attention to the correct phase sequence. Also, ensure the equipment is properly grounded.
How to choose the control mode of the VT307-5DZ1-01F-Q smc solenoid valve?
Selection Based on Application Requirements: For applications requiring high-precision speed control, choose the sensorless vector control mode; for general constant speed control applications, choose the V/F control mode.
Control Mode Features: The sensorless vector control mode can achieve high-precision speed and torque control, suitable for applications with high control accuracy requirements. The V/F control mode is simple and easy to use, suitable for general constant speed control.
Parameter Settings: After selecting the control mode, set the corresponding parameters according to specific application requirements to achieve the best control effect.
How to set the frequency setting channel of the smc solenoid valve?
Frequency Setting Method: The frequency can be set through the smc solenoid valve panel, external analog signals, or digital signals. Users can choose the appropriate frequency setting method according to actual application requirements.
Signal Source Requirements: When setting the frequency setting channel, ensure the stability and accuracy of the signal source. For example, when using external analog signals for frequency setting, ensure the stability and interference resistance of the signal.
Parameter Configuration: According to the selected frequency setting method, perform the corresponding parameter configuration. For example, for external analog signal setting, set the input range of the signal and the corresponding frequency range.
FAQ
1.Who are We?
Beijing Zhongping Technology Co., LTD., is a one-stop integrated service provider of intelligent manufacturing, belongs to the Gong Doctor Group, is a scientific research, design, marketing, technical services, industrial Internet, international import and export services as one of the science and technology companies.
2.What can you buy from us?
PLC, inverter, human-machine interface, hydraulic products, low-voltage power distribution, industrial robots and core components
3.Is the item in stock or need to be purchased from another supplier?
We have a large inventory of goods and have our own warehouse.
4.What advantages do we have over other suppliers?
Our company has a large amount of inventory and a number of warehouses, but also in the country's important industrial provinces and cities with offices and a number of overseas service points. To provide you with intelligent manufacturing one-stop comprehensive services, save efforts, labor and cost.
5.Can you provide 100% new original authentic products?
We only sell new original genuine, no renovation, no fake, only for the original factory original!
6.How long is the delivery time?
If there is a stock, it will take 2-3 working days to ship, if the quantity is large, it will take 5-7 working days after receiving the payment, if it is not a conventional model, it will take some time, we will inform you of the specific delivery time.
7.Is there technical support available?
Of course, we have a professional technical team that can help you solve technical problems.
8.How do we guarantee quality?
We have three processes to control the quality of goods.
1). Our engineers will inspect the production and quality control in the factory regularly.
2) Incoming materials shall be inspected by experienced purchasing engineers before they can be stored.
3). At least 2 people in the logistics department cross-check the goods to be sent before delivery.
9.Can you guarantee the safe and reliable delivery of your products?
Yes, we strictly adopt the international standard packing. We also use special packaging for dangerous goods, and refrigerated shipping for items with temperature requirements. Special item packaging and general cargo standard packaging requirements may incur additional costs.
10.How about the freight?
The cost depends on how you choose to get the goods. Express is usually the fastest but also the most expensive way. Sea freight is the best solution for large quantities of goods. The exact shipping cost depends on the purchase amount、quantity and weight of your order. Please feel free to contact us for more information.