YOULI Multiway valve - Multiway valve regulation method
Published:2023-09-07 17:24:41
1. Under normal conditions, before the hydraulic multiway valve leaves the factory, its opening pressure should be adjusted one by one to the setting value required by the user. If the user puts forward the working pressure level of the spring, it should be adjusted according to the lower limit value of the pressure level.
2, before the user installs the multiway valve on the protected equipment or before installation, it must be adjusted at the installation site to ensure that the setting pressure value of the valve meets the requirements.
3. Within the range of the working pressure level of the spring indicated on the nameplate, the opening pressure can be adjusted by rotating the adjusting screw to change the compression of the spring.
4. Before rotating the adjusting screw, the valve inlet pressure should be reduced to less than 90% of the opening pressure to prevent the valve disc from being driven to rotate when rotating the adjusting screw, resulting in damage to the sealing surface.
5. In order to ensure the accuracy of the opening pressure value, the medium conditions, such as the type of medium and temperature, should be adjusted as close as possible to the actual operating conditions. When the type of medium changes, especially when the medium accumulates in a different state (for example, from a liquid phase to a gas phase), the opening pressure often changes. When the operating temperature rises, the opening pressure is generally reduced.
6, therefore, when adjusted at room temperature and used for high temperature, the setting pressure value at room temperature should be slightly higher than the required opening pressure value. The degree to which it is high is related to the valve structure and material selection, and should be based on the manufacturer's instructions.
7, basically all multi-way valves have a place to adjust the pressure, its nature is basically the same as the diesel pump, the valve itself is also a place to adjust the flow and pressure. Although there are a variety of valves, basically there will be a protruding screw on one side of the valve, a large nut on the outside and a hex screw on the inside.
-
202301-13
How to choose Omron relay
1, select the rated working current of electromagnetic relay coil: DC electromagnetic relay driven by transistor or integrated circuit, the rated working current of the coil (generally 2 times of the ···
-
202302-13
Mitsubishi PLC communication detection steps
When you are ready to communicate through the AJ71QE71, perform the ping procedure in MS-DOS mode before starting the communication with Mitsubishi PLC's GPPW to see if the connection is correct. ···
-
202302-27
Delta servo motor how to choose?
In the selection of Delta servo motor, in principle should be based on the load conditions to choose. There are two kinds of loads on the motor shaft, namely damping torque and inertia load. The two l···
-
202302-27
How does Delta inverter adjust the frequency?
Delta frequency converter, frequency adjustment is mainly operated in the control panel, process:1. Press the Menu button to enter the parameter programming menu.2, P0.01=1, input this parameter to co···
-
202309-22
WEINVIEW touch screen response slow inspection method
1, view the appearance of the WEINVIEW touch screen: Observe whether there is dirt, fingerprints or scratches on the appearance of the WEINVIEW touch screen, which may affect the sensitivity and accur···