How does Delta inverter adjust the frequency?
Published:2023-02-27 16:23:10
Delta frequency converter, frequency adjustment is mainly operated in the control panel, process:
1. Press the Menu button to enter the parameter programming menu.
2, P0.01=1, input this parameter to complete the panel button correction frequency,;
3, P0.01=0, input this parameter can complete the panel to imitate the potentiometer correction frequency;
4. After correcting parameters, press ENTER button to acknowledge, and then press MENU button to exit to 0.00 frequency display condition.
5, use the panel button to correct the frequency, press the upward triangle button to increase the frequency.
** Low operating frequency: that is, the minimum speed of the motor operation. When the motor works at a low speed, its heat dissipation function is very poor. If the motor works at a low speed for a long time, the motor will be burned. And at low speeds, the current in the cable will increase, which will also lead to cable heating.
** High operating frequency: general frequency converter ** high frequency to 60Hz, and some even to 400 Hz, high frequency will make the motor high-speed operation, which for general motors, the bearing can not exceed the external speed operation for a long time, whether the rotor of the motor can accept such centrifugal force.
Carrier frequency: The higher the carrier frequency is set, the greater the weight of the higher harmonics, which is closely related to the length of the cable, motor heating, cable heating, frequency converter heating and other factors.
-
202302-17
959698 reasons for failure of Siemens 3RW44 soft starter
3RW44 Soft starter 95,96,98 is a comprehensive fault, what causes it to operate?95,96,98 reasons for failure of Siemens 3RW44 soft starter95,96,98 is the normally open normally closed integrated fault···
-
202308-10
Maintenance steps of Eston Palletizing robot
One: machine cleaningFirst, disconnect the power supply and remove debris around the machine. Wipe the surface of the machine with a clean cloth to ensure that there is no dust, grease and other impur···
-
202305-19
Mitsubishi PLC control inverter method
First, Mitsubishi plc analog signal control frequency converterHardware: fx1n type, fx2n type plc host, equipped with a simple FX1N-1DA-BD extended analog output board; Or analog input/output mixed mo···
-
202301-12
Delta UPS uninterruptible power supply basic conditions
1. Visually inspect the UPS and battery (or other energy storage) equipment for obstructions and properly cool the surrounding area.2. Ensure that there is no abnormal operation or warning on the UPS ···
-
202302-28
Omron plc maintenance procedures and equipment regular cleaning regulations
I. Maintenance procedures, regular equipment testing and adjustment regulations(1) Check the connection of wiring terminals in the PLC cabinet every half a year or quarter. If loose places are found, ···