Technical data
SIMATIC S7-1500, analog output module analog output 8xU/I high-speed type, 16-bit resolution, accuracy 0.3%, 8 channels, divided into groups, each group of 8, diagnosis; The replacement value of 8 channels was oversampled at 0.125ms; Modules support safe disconnection of load groups to SIL2 according to ENIEC 62061:2021 and Category 3 / PL d according to EN ISO 13849-1:415. The scope of supply includes feed elements, shielding brackets and shielding terminals: front connectors (screw type terminals or in-line) ordered separately
General information
Product type logo AQ 8xU/I HS
Hardware Function Status FS01 or later
The firmware version is V2.1.0
● Updatable firmware is
Product function
● I&M data is; I&M0 to I&M3
● Clock synchronization mode Yes
● Start by priority No
● Variable output range No
packaged
● STEP 7 TIA port, configurable/integrated, since version V14 / -
● STEP 7 Configurable/integrated, since version V5.5 SP3 / -
● PROFIBUS version GSD Edition/GSD revision V1.0 / V5.1
● PROFINET version GSD version/GSD revision above v2.3 / -
Operating mode
● Oversampling yes
● The MSO is
CiR configuration in action
Parameter assignment can be changed in RUN mode
Can be calibrated in RUN mode Yes
Supply voltage
Rating (DC) 24 V
Allowable range, lower limit (DC) 19.2 V
The upper limit (DC) is 28.8V
Reverse polarity protection is
Input current
Consumption current, maximum 320 mA; 19.2 V power supply
power
The power output from the backplane bus is 1.15W
Power loss
Power loss, typical value 7 W
Analog output
The number of analog outputs is 8
Voltage output, short circuit protection is
Voltage output, short circuit current, Max. 45 mA
Current output, no-load voltage, Max. 20 V
Minimum cycle time (for all channels) of 125 µs; It is independent of the number of active channels
Output range, voltage
● 0 to 10 V is
● 1 V to 5 V Yes
● -5 V to +5 V No
● -10 V to +10 V Yes
Output range, current
● 0 to 20 mA Yes
● -20 mA to +20 mA Yes
● 4 mA to 20 mA Yes
Actuator connection
● For two wire interface voltage output is
● For four wire interface voltage output is
● For the two-wire interface current output is
Load resistance (in rated output range)
● Minimum voltage output 1 kΩ
● Capacitance load at voltage output, Max. 100 nF
● The maximum value of current output is 500 Ω
● Inductive load at current output, maximum 1 mH
Conductor length
● Shielding, maximum 200 m
Composition of analog values at the output end
Integration and conversion time/resolution per channel
● Resolution (bits including symbols) with overmodulation, up to 16 bits
● Conversion time (per channel) 50µs; It is independent of the number of active channels
Starting time
● For resistance load 30 µs; See additional instructions in the manual
● For capacitive load 100 µs; See additional instructions in the manual
● For inductive load 100 µs; See additional instructions in the manual
Error/accuracy
Output ripple (dependent on output range, bandwidth 0 to 50 kHz), (+/-) 0.02%
Linear error (dependent on output range), (+/-) 0.15%
Temperature error (dependent on output range), (+/-) 0.002 %/K
The maximum value is -100 dB
Repetition accuracy (dependent on output range) at starting vibration at 25 °C, (+/-) 0.05%
When the temperature is below 0°C, the consumption error and temperature error data will be doubled
Operating error limits throughout the temperature range
● Voltage, related to output range, (+/-) 0.3 %
● Current, related to output range, (+/-) 0.3 %
Basic error limit (operating error limit at 25 °C)
● Voltage, related to output range, (+/-) 0.2 %
● Current, related to output range, (+/-) 0.2 %
Isochronous mode
The minimum processing and activation time (TWA) is 100 µs
Bus cycle time (TDP) is minimum 250 µs
Alarm/diagnosis/status information
The diagnostic function is
The accessible alternative value is
alarm
● Diagnostic alarm Yes
diagnosis
● Power supply voltage monitoring is
● The broken line is; Current output type only
● Short circuit is; Voltage output type only
● Overflow/Underflow Yes
Diagnostic display LED
● RUN LED Yes; Green LED
● ERROR LED Yes; Red LED
● Power supply voltage monitoring (PWR-LED) is; Green LED
● Channel status display is; Green LED
● For channel diagnosis is; Red LED
● For module diagnosis is; Red LED
Potential isolation
Potential separation of channels
● Between channels no
● Between channels, group the number of points 8
● Between the channel and the backplane bus
● Between the channel and the load voltage L+
The allowable potential difference
DC 8 V between S and MANA (UCM)
insulation
Insulation test, using 707 V DC (test type)
Standards, licenses, certificates
Standard components for safety shut-off are; FS04 or later
Safety off The maximum level of safety that a standard component can achieve
● The performance level complies with ISO 13849-1 PL d
● The class complies with ISO 13849-1 Class 3
● SIL 2 in accordance with IEC 62061
Environmental requirements
Operating ambient temperature
● Horizontal installation, minimum value -30 °C; FS03 or later
● Horizontal installation, maximum 60 °C
● Vertical installation, minimum value -30 °C; FS03 or later
● Vertical installation, maximum 40 °C
Operating height with reference to sea level
● Maximum elevation installation height of 5 000 m; The installation height is greater than 2000 m. For details, see the manual
dimension
Width 35mm
Height 147mm
Depth 129 mm
weight
Weight, about 325 g
FAQ
1.Who are We?
Beijing Zhongping Technology Co., LTD., is a one-stop integrated service provider of intelligent manufacturing, belongs to the Gong Doctor Group, is a scientific research, design, marketing, technical services, industrial Internet, international import and export services as one of the science and technology companies.
2.What can you buy from us?
PLC, inverter, human-machine interface, hydraulic products, low-voltage power distribution, industrial robots and core components
3.Is the item in stock or need to be purchased from another supplier?
We have a large inventory of goods and have our own warehouse.
4.What advantages do we have over other suppliers?
Our company has a large amount of inventory and a number of warehouses, but also in the country's important industrial provinces and cities with offices and a number of overseas service points. To provide you with intelligent manufacturing one-stop comprehensive services, save efforts, labor and cost.
5.Can you provide 100% new original authentic products?
We only sell new original genuine, no renovation, no fake, only for the original factory original!
6.How long is the delivery time?
If there is a stock, it will take 2-3 working days to ship, if the quantity is large, it will take 5-7 working days after receiving the payment, if it is not a conventional model, it will take some time, we will inform you of the specific delivery time.
7.Is there technical support available?
Of course, we have a professional technical team that can help you solve technical problems.
8.How do we guarantee quality?
We have three processes to control the quality of goods.
1). Our engineers will inspect the production and quality control in the factory regularly.
2) Incoming materials shall be inspected by experienced purchasing engineers before they can be stored.
3). At least 2 people in the logistics department cross-check the goods to be sent before delivery.
9.Can you guarantee the safe and reliable delivery of your products?
Yes, we strictly adopt the international standard packing. We also use special packaging for dangerous goods, and refrigerated shipping for items with temperature requirements. Special item packaging and general cargo standard packaging requirements may incur additional costs.
10.How about the freight?
The cost depends on how you choose to get the goods. Express is usually the fastest but also the most expensive way. Sea freight is the best solution for large quantities of goods. The exact shipping cost depends on the purchase amount、quantity and weight of your order. Please feel free to contact us for more information.