Maintenance points of Omron relay
Published:2023-02-01 15:32:10
1. The shell surface of the Omron relay used in installation should be free of scratches, cracks and damage. In case of serious damage, the intact relay with the same specifications should be replaced in time;
2. In the maintenance process of Omron relay, it is necessary to check whether the contact of Omron relay is broken or bright. If abnormal situation is found, maintenance personnel should timely deal with it;
3. Carefully check whether there are foreign bodies such as welding slag and dust inside the Omron relay to avoid affecting the performance of the relay;
Four. Check whether the coil inside the Omron relay is broken, but also check whether all the connections are broken, whether the solder joint is full and wet;
5. Because the pin of relay is easy to be damaged, it is necessary to check regularly whether the pin of Omron relay has deformation, discoloration or other mechanical damage;
Vi. Check whether the fastener of Omron relay is loose. If the above phenomenon is found, the maintenance personnel should tighten it in time;
Vii. In the actual use of Omron relay, the locating pin and the base may loosen under certain circumstances, so it is necessary to check whether the locating pin and the base are consistent and whether they are loose. In the process of inspection, if loose phenomenon is found, corresponding measures should be taken in time.
-
202307-27
Siemens S7-200 SMART Common questions about serial communication
1. Does the S7-200 SMART support Modbus ASCII communication mode?STEP 7- The Micro/WIN SMART software does not provide the Modbus ASCII communication mode instruction library. If the S7-200 SMART CPU ···
-
202301-31
Delta overload trip fault solution
1. The main cause of VFD overload(1) Mechanical overload. The main characteristic of overload is the motor heating, which can be found by reading the running current on the display screen.(2) The unba···
-
202302-16
Solution of MCGS communication problem
1. How to check the communication status of the device in Kunlun Mode (MVGS)In all MCGS non-board devices (except some custom devices), *** channels are communication channels. That is, after entering···
-
202303-08
Cause of frequent trip of Schneider leakage switch
1. Bad deviceEach pile lead wire is not firmly connected, long-term loose, will cause the pile head heat, oxidation, burn the outer insulation of the wire, and announce the spark and coke taste, the f···
-
202212-29
Failure analysis of WEINVIEW touch screen can not be turned on
1. The power cable is incorrectly connectedThis may seem obvious, but make sure the power cord is connected to the back of the touch screen and plugged into a power outlet. If it looks connected corre···