How to maintain MCGS touch screen
Published:2023-02-09 14:36:33
1. Wipe the phone screen with a dry cloth before opening it every day.
2. Drinks or drops falling on the screen will cause the software to stop the reaction. This is because water droplets and fingers have similar properties and it is necessary to wipe the water droplets.
3, Kunlun mcgs screen program can automatically detect how much dust, too much dust will reduce the sensitivity of the touch screen, just wipe the screen with dry cloth and alcohol.
4. Wipe the touch screen with a dirty, greasy fingerprint.
5, strictly in accordance with the relevant rules to open and close the system power supply, that is, to open a power supply sequence is: monitor, audio, host. Turn off the power in reverse order.
6, generate a large number of temporary files on the hard disk, if you often do not exit Windows, the MCGS mcgs touch screen will be periodically closed directly, therefore, you need to regularly run the disk scan program to scan the hard disk error, for example, in the order specified, click the four corners.
7, pure touch screen control program design does not need to go through the mouse cursor, cursor company will only distract the user.
8. Choose a simple mouse-prevention mode, which is sufficient for your application, since complex modes require sacrificing latency and system resources.
9. In windows, users can access other systems and start slower applications at the same time. The solution is to modify the system, file: shell progman, shell explorer.exe, Exe (on windows 95) is changed directly to an Exe file, however, the application should be able to exit the window directly, otherwise the system will not be able to exit.
10. In harsh environments, periodically open, clean and reflect stripes on the inner surface of the MCGS mcgs touch screen. The specific method is: open the cover side of the machine to find the release mechanism, the opening mechanism is released by the bolt, lift the front part of the machine head, the control card can be seen, the touch screen, the touch screen unplug, and take out the head and the head retracted by the touch screen. In the fixed touch screen method, after a careful look, take out the clean touch screen, take care not to use cardboard or hard cloth, do not scratch the reflective stripes, in the reverse order to restore the original configuration.
-
202306-09
ABB robot program running speed slow repair steps
1, check whether the program contains logical instructions (or other instructions that "take no time" to execute), because such programs will cause execution loops when conditions are not me···
-
202302-06
Siemens Soft Starter 3RW44 can self-reset can be fault
Not all faults can be self-reset. The faults that can be self-reset are as follows (The method of self-reset is to set the corresponding parameters in the menu of the LCD screen) :1) Motor thermal mod···
-
202411-19
what is plc?programmable logic controller meaning
In today's industrial production,PLC has become more and more important and common,but many people do not have a very clear understanding of it.Today,we will introduce PLC in detail from all aspec···
-
202301-06
Fault analysis and maintenance steps of WEINVIEW touch screen failure to turn on
1. The power cable is incorrectly connectedThis may seem obvious, but make sure the power cord is connected to the back of the touch screen and plugged into a power outlet. If it looks connected corre···
-
202303-02
Mitsubishi Inverter alarm history confirmation and clearance
When the FR-CS80 converter detects an anomaly, it will display fault information or alarm in the operation panel according to the abnormal content, or maintain functional action and block the output o···