The characteristics of Schneider explosion-proof inverter box
Published:2023-01-09 17:24:58
1. Aluminum alloy shell or steel plate welding, plastic spraying appearance;
2. Built-in inverter, circuit breaker, signal light and other components produced by domestic or Schneider companies;
3. It is mainly through changing its output frequency to adjust the general three-phase asynchronous motor speed, in order to reach the production process requirements or complete the purpose of power saving, power saving rate up to 30%-60%, can also be used as a motor soft start controller, but also through the sensor, transmitter and other control circuit composed of closed-loop speed control system, device operation is simple, power factor is stable, Partner has a variety of functions such as fault display;
4. With over current, short circuit, over voltage, under voltage, broken equal maintenance, digital display frequency, speed and load rate or current, can be manually adjusted frequency, can set speed according to the time change process curve, can also be given by DCS system signal to control its frequency;
5. Steel pipe or cable wiring with long explosion-proof is a professional engaged in explosion-proof appliances, explosion-proof lighting distribution box, explosion-proof power distribution box, explosion-proof repair box, explosion-proof distribution box, stainless steel explosion-proof distribution box, waterproof and dustproof anticorrosive distribution box, explosion-proof operation column, waterproof and dustproof anticorrosive operation column, explosion-proof air conditioning, explosion-proof axial flow fan, explosion-proof lamps, explosion-proof flashlight, explosion-proof repair power box, Explosion-proof power inspection box, explosion-proof junction box, explosion-proof wire piercing box, explosion-proof flexible connection receiver, explosion-proof magnetic starter, explosion-proof circuit breaker.
-
202212-29
Schneider instrument maintenance precautions
1. When installing and adjusting the appearance, the original status should be recorded in order to recover.2, repair the appearance of fine instruments, such as accidentally small parts flying, shoul···
-
202301-30
ABB frequency converter fault code
1. ABB inverter fault code: 0001Cause: The output current exceeds the trip valueMeasures: Check motor load, check acceleration time, check motor and motor cable (including phase sequence).2. ABB inver···
-
202302-17
959698 reasons for failure of Siemens 3RW44 soft starter
3RW44 Soft starter 95,96,98 is a comprehensive fault, what causes it to operate?95,96,98 reasons for failure of Siemens 3RW44 soft starter95,96,98 is the normally open normally closed integrated fault···
-
202301-31
Delta overload trip fault solution
1. The main cause of VFD overload(1) Mechanical overload. The main characteristic of overload is the motor heating, which can be found by reading the running current on the display screen.(2) The unba···
-
202302-20
This section describes how to set the bios of Advantech mainboard
1. Set the system date and timeOn the standard BIOS setting screen, press arrow keys to move the cursor to Date and Time, and then press Page Up/Page Down or +/&S722 to correct the date and time o···