The characteristics of Schneider explosion-proof inverter box
Published:2023-01-09 17:24:58
1. Aluminum alloy shell or steel plate welding, plastic spraying appearance;
2. Built-in inverter, circuit breaker, signal light and other components produced by domestic or Schneider companies;
3. It is mainly through changing its output frequency to adjust the general three-phase asynchronous motor speed, in order to reach the production process requirements or complete the purpose of power saving, power saving rate up to 30%-60%, can also be used as a motor soft start controller, but also through the sensor, transmitter and other control circuit composed of closed-loop speed control system, device operation is simple, power factor is stable, Partner has a variety of functions such as fault display;
4. With over current, short circuit, over voltage, under voltage, broken equal maintenance, digital display frequency, speed and load rate or current, can be manually adjusted frequency, can set speed according to the time change process curve, can also be given by DCS system signal to control its frequency;
5. Steel pipe or cable wiring with long explosion-proof is a professional engaged in explosion-proof appliances, explosion-proof lighting distribution box, explosion-proof power distribution box, explosion-proof repair box, explosion-proof distribution box, stainless steel explosion-proof distribution box, waterproof and dustproof anticorrosive distribution box, explosion-proof operation column, waterproof and dustproof anticorrosive operation column, explosion-proof air conditioning, explosion-proof axial flow fan, explosion-proof lamps, explosion-proof flashlight, explosion-proof repair power box, Explosion-proof power inspection box, explosion-proof junction box, explosion-proof wire piercing box, explosion-proof flexible connection receiver, explosion-proof magnetic starter, explosion-proof circuit breaker.
-
202302-02
Mitsubishi inverter overload fault judgment method
1. Check whether the three-phase power of the motor is balanced(1) If the three-phase voltage of the motor is not balanced, the three-phase voltage of the output end of the Mitsubishi inverter should ···
-
202212-29
Test method for Delta Circuit breakers AC contactors and frequency converters
1. Circuit breakerThe circuit breaker is a device that can be operated manually or automatically. It is used to control the on-off of the system power supply in the circuit system of the device. When ···
-
202302-23
Schneider inverter commissioning procedure
1. Type recognition: Whether the type of frequency converter is common with the type of frequency converter purchased.2. Transportation admission: After opening the package, check whether the frequenc···
-
202308-31
What are the applications of CASAPPA synchronous motors?
1, as a flow distribution device, according to the system requirements to distribute the output flow of the pumpIf the shaft is equipped with multiple sets of plain bearings, it is required to ensure ···
-
202301-10
Failure analysis of Mitsubishi Frequency Converter OC1 and OC3
Many times when Mitsubishi frequency converter presents OC (overcurrent problem), it is caused by the following reasons. Take A500 series frequency converter as an example:1) Caused by improper parame···