Siemens SINAMICS G120 modular inverter advantages
Published:2023-08-18 15:49:06
1. Modular design creates a high degree of flexibility to adapt to future requirements for drive solutions
The control unit can be replaced with power (hot swap)
Use plug terminals
The procedure for replacing the device is simple and easy to maintain
2. Safety features are integrated, so the cost of integrating the drive into the machinery or equipment with safety solutions is significantly reduced
3. Support PROFINET or PROFIBUS communication based on PROFIdrive Profile 4.0
Plant wide engineering design can be realized
Easy to handle
4. With innovative loop design (two-way input rectifier and "reduced capacity" DC bus), the kinetic energy of the load can be returned to the power supply system when using the power module PM250. Because of the feedback capability, there is no need to convert regenerative energy to heat through the brake resistance, resulting in a significant reduction in energy consumption.
5. Integrated USB interface, making local debugging and diagnosis easier
6. Integrated features for pump, fan and compressor applications, such as:
4 freely programmable PID controllers
Application-specific wizard
Equipped with Pt1000/LG-Ni1000 temperature sensor interface
AC 230 V relay
3 freely programmable digital timing switches
7. With CU250S-2 control unit: Integrated positioning function (basic locator EPos) can realize positioning tasks with high dynamic characteristics during operation. Positioning can be achieved by incremental encoders or/and ** value encoders (SSI)
-
202306-01
The main function and composition of the configuration software of MCGS Tong - state embedded edition are introduced
The main function of MCGS embedded configuration software1. Simple and flexible visual operation interface: all Chinese and visual development interface is adopted, which meets the usage habits and re···
-
202302-10
Parameter interpretation of Omron relay
Rated working voltage (current) :Also known as coil voltage, it refers to the voltage or current that the relay can work reliably. When the relay is working, the input voltage or current of the relay ···
-
202212-30
What are the main items of Omron plc overhaul?
1. Check the power supply. Check whether the voltage change range at the power terminal is within the allowable ±10% range.2. Work environment. Focus on checking whether the temperature, humidity, vi···
-
202301-13
Working principle and application of Omron relay
Working principleWhen a certain voltage is added to both ends of the coil, a certain current will flow through the coil, resulting in electromagnetic effect. Under the action of electromagnetic force ···
-
202307-20
Common faults and treatment methods of rkc temperature controller
1, the power indicator is normal, but the temperature controller has no screen display. This fault is mostly caused by the temperature controller on the voltage regulator (7805 or 7812) in the long-te···