Siemens SINAMICS G120 modular inverter advantages
Published:2023-08-18 15:49:06
1. Modular design creates a high degree of flexibility to adapt to future requirements for drive solutions
The control unit can be replaced with power (hot swap)
Use plug terminals
The procedure for replacing the device is simple and easy to maintain
2. Safety features are integrated, so the cost of integrating the drive into the machinery or equipment with safety solutions is significantly reduced
3. Support PROFINET or PROFIBUS communication based on PROFIdrive Profile 4.0
Plant wide engineering design can be realized
Easy to handle
4. With innovative loop design (two-way input rectifier and "reduced capacity" DC bus), the kinetic energy of the load can be returned to the power supply system when using the power module PM250. Because of the feedback capability, there is no need to convert regenerative energy to heat through the brake resistance, resulting in a significant reduction in energy consumption.
5. Integrated USB interface, making local debugging and diagnosis easier
6. Integrated features for pump, fan and compressor applications, such as:
4 freely programmable PID controllers
Application-specific wizard
Equipped with Pt1000/LG-Ni1000 temperature sensor interface
AC 230 V relay
3 freely programmable digital timing switches
7. With CU250S-2 control unit: Integrated positioning function (basic locator EPos) can realize positioning tasks with high dynamic characteristics during operation. Positioning can be achieved by incremental encoders or/and ** value encoders (SSI)
-
202302-24
WEINVIEW touch screen common faults and maintenance
(1) The startup indicator is normal, but the display shows no signal input (black screen);(2) Press the on key, the host does not have any response (the indicator light is not bright, the host startup···
-
202308-31
What are the applications of CASAPPA synchronous motors?
1, as a flow distribution device, according to the system requirements to distribute the output flow of the pumpIf the shaft is equipped with multiple sets of plain bearings, it is required to ensure ···
-
202302-06
Siemens Soft Starter 3RW44 can self-reset can be fault
Not all faults can be self-reset. The faults that can be self-reset are as follows (The method of self-reset is to set the corresponding parameters in the menu of the LCD screen) :1) Motor thermal mod···
-
202307-20
Common faults and treatment methods of rkc temperature controller
1, the power indicator is normal, but the temperature controller has no screen display. This fault is mostly caused by the temperature controller on the voltage regulator (7805 or 7812) in the long-te···
-
202303-08
Cause of frequent trip of Schneider leakage switch
1. Bad deviceEach pile lead wire is not firmly connected, long-term loose, will cause the pile head heat, oxidation, burn the outer insulation of the wire, and announce the spark and coke taste, the f···