Siemens SINAMICS G120 modular inverter advantages
Published:2023-08-18 15:49:06
1. Modular design creates a high degree of flexibility to adapt to future requirements for drive solutions
The control unit can be replaced with power (hot swap)
Use plug terminals
The procedure for replacing the device is simple and easy to maintain
2. Safety features are integrated, so the cost of integrating the drive into the machinery or equipment with safety solutions is significantly reduced
3. Support PROFINET or PROFIBUS communication based on PROFIdrive Profile 4.0
Plant wide engineering design can be realized
Easy to handle
4. With innovative loop design (two-way input rectifier and "reduced capacity" DC bus), the kinetic energy of the load can be returned to the power supply system when using the power module PM250. Because of the feedback capability, there is no need to convert regenerative energy to heat through the brake resistance, resulting in a significant reduction in energy consumption.
5. Integrated USB interface, making local debugging and diagnosis easier
6. Integrated features for pump, fan and compressor applications, such as:
4 freely programmable PID controllers
Application-specific wizard
Equipped with Pt1000/LG-Ni1000 temperature sensor interface
AC 230 V relay
3 freely programmable digital timing switches
7. With CU250S-2 control unit: Integrated positioning function (basic locator EPos) can realize positioning tasks with high dynamic characteristics during operation. Positioning can be achieved by incremental encoders or/and ** value encoders (SSI)
-
202307-07
The alarm code cause and diagnosis method of the cabinet air conditioner of Rittal
Alarm code: A01System message: Open the cabinet doorAir conditioning cause: The opening and closing position is incorrectDiagnostic method: Check the transition position of the door and, if necessary,···
-
202303-08
How to choose Schneider Circuit Breaker?
First calculate the current value of each branchPure resistive load, such as light bulbs, electric heaters, etc., with the indicated power directly divided by the voltage, the formula I= power /220v; ···
-
202302-24
WEINVIEW prompts the solution to the download mode error
1. Software editing - System Parameter setting -HMI attribute - Port number: 8000 Change, such as 9000;2. Call up the computer Task Manager -- end the process com_e30.exe;3. Restart the computer;4. Qu···
-
202306-30
Advantech motherboard how to enter the U disk starter
If you can access the operating system before reinstalling the industrial computer system, you should back up important data and drivers to avoid the loss of important files due to system reinstallati···
-
202212-29
Mitsubishi plc and computer communication setting method
Open the Mitsubishi plc programming software, menu "Online" -- >" transmission Settings "inside to select your connection method.1, first Mitsubishi plc and computer connection ···